Calculation
Loads, sizing, and capacity calculations tied to policy — every value cites the clause and version it derives from.
The single most policy-sensitive module in design. Structural loads, MEP loads, transformer sizing, pump capacity, HVAC heat load, diversity factor application — all done against the org's policy library (MEP-04 HVAC, MEP-07 Electrical, structural policy). Every calculation result carries the policy clause and version it derives from. Deviations require explicit approval. A policy update propagates to all open calculations.
- ·Concept design approved in M07 — calculation kickoff
- ·New drawing revision published in ACC
- ·policy version update (MEP-04, MEP-07, structural)
- ·Calculation review cycle by discipline head
- ·Deviation requested by consultant against policy
- ·Project segment (drives MEP-07 diversity factor selection)
- ·Drawing version from M07 with model geometry and layout
- ·policy library — MEP-04 (HVAC), MEP-07 (Electrical), structural policy, façade policy
- ·Project configuration — areas, occupancy, equipment lists
- ·Previous-project calculation history for similar configurations
- ·BIM model snapshot for quantity and geometry input
- ·Equipment schedule from consultant
- ·Connected-load list per discipline
- ·Project segment and product mix specification
- ·Policy-anchored calculation — every value carries the clause and version it derives from
- ·Diversity factor application by segment (D1=0.45/0.48/0.50 for Gold/Platinum/Diamond)
- ·Multi-discipline reconciliation — structural feeds MEP feeds façade
- ·Deviation register with explicit approval workflow
- ·Auto-propagation of policy updates to all open calculation sheets
- ·MEP-04 V11 — HVAC design standards
- ·MEP-07 V17 — Electrical design standards including diversity factors
- ·Structural design policy with seismic and wind code references
- ·Façade structural and thermal policy
- ·Deviation approval policy — what requires Design Head, what requires MD
- ·Every calculation result cites its policy clause and version
- ·Policy deviation requires explicit approval — silent deviations rejected
- ·Cross-discipline conflict resolved before sign-off, not after
- ·Sign-off requires discipline-head review, not just consultant submission
- ·Discipline-wise calculation sheets with policy citations
- ·Sizing summary feeding BOQ (loads, capacities, equipment specifications)
- ·Deviation register with approvals
- ·Policy citation log per project
- ·Project calculation record updated per discipline
- ·Sizing summary feeds M10 BOQ generation
- ·Policy citation history feeds the standards library
- ·Sizing outputs trigger BOQ generation in M10
- ·Equipment specifications feed spec library reference in M09
- ·Sized loads drive procurement requirements in M14
- ·Policy update propagates re-validation across all open calculations
- Structure consultantStructural load and sizing
- MEP consultantMEP loads and equipment sizing
- Façade consultantFaçade load and panel sizing
- MEP DesignPolicy compliance review
- Standards teamPolicy authoring and maintenance
- Design HeadCalculation sign-off and deviation approvals
- 01Structural load calculations — dead, live, wind, seismic
- 02Structural sizing — slabs, beams, columns, foundations
- 03MEP load calculations — connected load, demand load per MEP-07
- 04Transformer and DG sizing — diversity factors D1, D2, D3 from policy
- 05Pump capacity calculations
- 06HVAC heat load per MEP-04
- 07Diversity factor application — segment-specific D1 (0.45/0.48/0.50)
- 08Calculation sign-off with policy citations
Calculations done in vendor spreadsheets; deviations from policy not flagged; assumptions invisible.
Every value cites the policy clause; deviations require approval; policy updates propagate.
Worli MEP-07 calculation. Connected load 2,840 kW. Diversity factor D1 = 0.48 for Platinum segment (MEP-07 V17 clause 4.2). Demand load 1,363 kW. Transformer sizing 1,500 kVA per policy. Calculation signed off citing 12 policy clauses across MEP-04 V11 and MEP-07 V17.
- ·Calculation sheets per discipline
- ·Policy citation log
- ·Deviation register (with approvals)
- ·Sizing summary feeding BOQ
Calculations come back from consultants in spreadsheets. The org's policy is referenced inconsistently. Deviations are silent — caught only by MEP review, often late. Same calculation re-derived every project.
No external system integrations — module operates on internal records.